In data centers, humidifiers primarily ensure that electrostatic discharges and damage to sensitive hardware are prevented.
In addition, evaporative coolers can be used in the exhaust air cooling system, thus significantly reducing operating costs for cooling the servers. The cooling effect achieved in the exhaust air is carried over to the intake air. Conventional cooling machines and cooling batteries can therefore be designed to be significantly smaller and more cost-effective. In addition to this, the ongoing operating costs for building cooling are reduced.
Schematic layout of the data center
Facebook in Luela, Sweden
Reduce energy costs
Indirect evaporative cooling in air conditioning systems is one way of generating regenerative cooling capacity. The reduction of the capacity and power requirement of a cooling machine for mechanical cooling through indirect evaporative cooling is based on the thermodynamic principle that air cools when it is humidified through the evaporation of water. The evaporation heat needed for the phase change of water is removed from the air and causes the desired cooling.
The potential energy savings of this efficiency measure can be determined using an energy simulation calculation based on exemplary system parameters and meteorological data for the location. The cooling effect achieved in the exhaust air is carried over to the intake air. Conventional cooling machines and cooling batteries can therefore be designed to be significantly smaller and more cost-effective. In addition to this, the ongoing operating costs for building cooling are reduced significantly. A PC or Android version is available free of charge at www.mycoolblue.de and an IOS version in the Apple App Store.
Example illustration of the energy contributions of an air conditioning system with evaporative cooling.
Calculated using the Coolblue 2.0 software tool from Condair.
Static charges
Static charge can occur during maintenance work, or on ungrounded components in the data center. This can lead to uncontrollable discharge shocks and the destruction of sensitive electrical components.
At a relative humidity of 50–55%, damp air increasingly settles on ions, making them heavier and less mobile in the electric field. The conductivity of the air and the material surfaces then increases, so that electrical charges are dissipated, which prevents the formation of potential differences.
Dry air below 40% RH can cause
electric potential differences
At 50–55% RH, electrical charges can
dissipate due to the increased conductivity
Condair quality
Our customized systems offer professional solutions for air humidification and dehumidification for the size and conditions of each individual room.
Because professional planning is the basis for functional quality and energy efficiency, we are happy to assist you right from the planning phase.
A hamam is a steam bath in which a special bathing ceremony is held,
and is an important part of Islamic bathing and physical culture.
The focus is...
Steam bath and steam shower
Nowadays, many hotels and health clubs offer spa facilities for the well-being of their guests and members:
A swimming pool, a sauna and more and mor...
Office Rooms
Employees must feel comfortable as they work. Motivation, efficiency, and health can be improved through contemporary design of the workplace. The ri...
Fashion Industry
An “electric shock” when touching a clothes rail; hair that takes on a life of its own when trying on clothes. Dry air can really spoil the fun of go...
Food Storage
Hygroscopic (moisture-drawing) foods interact with ambient humidity. They either absorb water vapor from their environment or give off water vapor.
T...
Electronic Industry
The dryer the air, the quicker electrostatic charges occur and the stronger they are. Consistent protection against ESD (electrostatic discharge) has...
Automotive Industry
To achieve optimum results, paintwork must be applied to vehicles in optimum environmental conditions. Crucially, humidity and temperature must meet ...
Call Centers
A good room air humidity in a call center not only ensures the employees’ well-being, but also their performance and health. Today, respiratory illne...
Museums
Museums are charged with the task of preserving treasures of humanity and art. The innumerable, often unique and irreplaceable exhibits are worth man...
Aerospace Industry
Reliable functional quality of all components is essential for the aerospace industry. Inadequate humidity can lead to damage and faults in electroni...